What features set Advanced ThermaCube
insulation apart?

Non-Corrosive. Glass fibers need no
fire-retardant chemicals that can promote corrosion of pipes, electrical equipment or
structural metal attachments. |
Doesn't Absorb Moisture. Moisture reduces
insulation effectiveness. Glass fibers resist moisture build-up. |
Noncombustible. Meets all model building
codes for noncombustibility. |
Doesn't Support Mold Growth.
Inorganic glass fiber does not support fungus or mold growth. Will not rot or
decay. Will not support an environment for vermin. |

Installation Specifications
Loose-fill insulations vary in thermal performance due to factors such as aging, mean
temperature, settlement, convection, moisture absorption and installation variation.
Convection in glass loose-fill insulation installed in open attics
can reduce its thermal performance at extreme winter temperatures during the heating
season.
Assured Thermal Performance. Advanced
ThermaCube Plus insulation is thermal-tested and labeled in strict accordance with current
ASTM loose-fill standards. The R-value stated on the label will be there when
installed to label specifications.
Product Compliances.
This product conforms to the product requirements of ASTM c764 Type I, Category 2.
The surface burning characteristics of this product have been determined in accordance
with ASTM E84: Flame Spread 5, Smoke Developed 5.
To Obtain
R-Value Of |
Minimum Bags/
1000 Net Sq. Ft. |
Maximum
Coverage/Bag
(Sq. Ft.) |
Minimum
Weight/Sq. Ft.
(Lbs.) |
Minimum
Thickness
(Inches) |
R-44
R-38
R-30
R-26
R-22
R-19
R-11 |
23.3
20.0
15.6
13.5
11.4
9.8
5.6 |
43
50
64
74
88
102
178 |
.822
.705
.550
.474
.399
.343
.197 |
18.5
16
12.75
11
9.5
8.25
4.75 |
|